Compact point-of-entry ultrafiltration at more than 2,000 litres per hour

Point-of-Entry Ultrafiltration

Filter particles and microorganisms / Without a storage tank

WATCH UF 2500® is a compact point-of-entry ultrafiltration system designed to reduce suspended particles, colloids and microorganisms from appropriately pretreated water.

The system uses a tubular ultrafiltration membrane with an absolute filtration rating of 20 nanometres, or 0.02 microns. Operating directly from suitable inlet pressure, WATCH UF 2500® provides a published flow of 2.2-2.7 m³/h at 25°C and 4 bar without requiring a treated-water storage tank or feed pump. It is available with manual or automatic backwashing and can be connected in parallel or series for larger commercial installations.

0.02-micron filtration / Compact, direct-flow performance

WATCH UF 2500 Introduction

One UF platform.
Multiple water-filtration applications.

Suitable for drinking-water, process-water and pretreatment applications where membrane-compatible inlet water and adequate system pressure are available.

Drinking and Process Water

Reduction of suspended particles, colloids, bacteria and cyst-sized organisms.

Reverse-Osmosis Pre-Filtration

Helps reduce particulate and microbiological loading before compatible RO systems.

Hotels and Restaurants

Point-of-entry filtration for hospitality and food-service properties.

Holiday Homes and Campsites

Compact filtration for seasonal properties and camping facilities.

Remote and Temporary Operations

Potential use at remote worksites, mining operations, logging camps and temporary facilities.

Agriculture and Emergency Supply

Filtration for suitable seasonal agricultural activities and emergency-water installations with appropriate disinfection safeguards.

Four filtration functions / Engineered into one compact system

UF

0.02-Micron Absolute Filtration (UF-20NM)

The tubular ultrafiltration membrane provides a published absolute rating of 20 nm for retaining particles, colloids and many microorganisms larger than the membrane pores.

OI

Outside-to-Inside Filtration (OUT-IN)

Feed water passes from the outside of the tubular membrane toward the filtered-water side, retaining contaminants on the membrane surface.

DF

No Storage Tank or Feed Pump (DIRECT-FLOW)

The system can operate directly from suitable line pressure without a separate treated-water storage tank or feed pump.

FB

Manual or Automatic Cleaning (FLEX-BACKWASH)

WATCH UF 2500® is available with manual or automatic backwashing. Optional components support filtered-water backwashing, chemical cleaning, disinfection and bypass operation.

How WATCH UF 2500 ultrafiltration works

Ultrafiltration uses pressure to move water through a porous membrane while retaining suspended material and microorganisms according to their effective size.

  • Size-Based Separation – The 0.02-micron absolute membrane barrier retains particles and organisms larger than the membrane’s rated pores while water and dissolved ions pass through.
  • Colloid and Turbidity Control – Fine suspended solids and colloidal particles accumulate at the membrane surface instead of passing into the filtered-water stream.
  • Microorganism Reduction – Log-reduction performance for bacteria, viruses and cysts depends on the test organism, protocol and operating conditions.
  • Backwash and Cleaning Recovery – Periodic backwashing removes accumulated deposits. More intensive cleaning or disinfection may be required when normal backwashing no longer restores flow.
WATCH UF 2500 Science and Technology
Model Specifications

WATCH UF 2500® Specifications

Comprehensive performance parameters, log reductions, and available system configurations.

Published Performance Specifications
Parameter Published Value
Filtration rating20 nm / 0.02 µm absolute
Flow rate2.2–2.7 m³/h at 25°C and 4 bar
Operating temperature2–50°C
Operating pressure1–8 bar
Backwash rate0.7 m³/h (~12 L/min)
Dimensions & Weight23 cm diameter × 145 cm height | 16 kg
ConnectionsMain: DN 25 (1″) | Cleaning: DN 10 (3/8″) | Drain: DN 20 (3/4″)
Required prefiltration5 µm (1 µm recommended)
Chlorine limitsMax service: 1.0 ppm | Max cleaning: 200 ppm
Microorganism reductionBacteria: 4.4 log (99.996%) | Viruses: 2.4 log (99.6%) | Cysts: ~2.0 log (~99%)
Available System Configurations
Version Article Number Valve Type Normal Flow Backwash Flow Connection
Automatic backwashingUFA.025.842Tech-Series2.2 m³/h12 L/minDN 25 / 1 inch
Manual backwashingUFM.025.842Manual2.2 m³/h12 L/minDN 25 / 1 inch

Explore our ultrafiltration poster library

Loading Poster Library…
WATCH UF 2500
2019

WATCH UF 2500®

Compact point-of-entry ultrafiltration with more than 2,000 litres per hour.

0.02-Micron Absolute Filtration
2026

0.02-Micron Absolute Filtration

Understanding the WATCH UF 2500 membrane barrier.

Outside-to-Inside Filtration
2026

Outside-to-Inside Filtration

How feed water moves through the tubular membrane.

Manual or Automatic Backwashing
2026

Manual or Automatic Backwashing

Two control options for different installation requirements.

RO Membrane Protection
2026

RO Membrane Protection

Ultrafiltration as a particulate and microbiological pretreatment stage.

Parallel Commercial Systems
2026

Parallel Commercial Systems

Connecting multiple UF modules for larger flow requirements.

Frequently
Asked Questions

Essential information about membrane performance, installation, backwashing, disinfection and system limitations.

Contact Support
What is WATCH UF 2500®?
It is a point-of-entry tubular ultrafiltration system with a published absolute membrane rating of 20 nm, or 0.02 µm.
What is the system’s normal flow rate?
The published flow is 2.2-2.7 m³/h at 25°C and 4 bar. Actual flow depends on pressure, temperature, inlet quality and membrane condition.
Does it need a storage tank or feed pump?
Not when sufficient and stable inlet pressure is available. Low-pressure or variable-demand applications may require additional equipment.
What does the membrane remove?
It reduces suspended solids, colloids, bacteria, cyst-sized organisms and some viruses according to its validated log-reduction performance.
Does ultrafiltration remove dissolved salts or hardness?
No. Dissolved minerals, hardness, nitrate, fluoride, arsenic and most dissolved chemicals can pass through an ultrafiltration membrane.
Is WATCH UF 2500 a complete water purifier?
It should only be described as a purifier if the complete system meets an applicable purifier protocol. The published 2.4-log virus and approximately 2-log cyst reductions do not support a universal pathogen-removal claim.
Is pretreatment required?
Yes. The brochure specifies 5-micron prefiltration and recommends 1-micron prefiltration.
What is the difference between manual and automatic backwashing?
The manual version requires operator-controlled cleaning, while the automatic version uses a Tech-Series valve and programmable cleaning sequence.
How frequently should the membrane be backwashed?
Frequency depends on turbidity, suspended solids, pressure loss and operating time. The manufacturer should provide a commissioning baseline and defined trigger limits.
Can chlorine be used?
The published maximum during service is 1.0 ppm, while up to 200 ppm is stated for cleaning. Concentration, contact time, pH and rinsing instructions must be defined.
Can several systems be connected together?
Yes. The brochure states that units can be manifolded in parallel or series for commercial applications, subject to correct hydraulic design.
Can it treat microbiologically unsafe source water by itself?
Do not assume so. CDC guidance notes that ultrafiltration removes bacteria and parasites but is only somewhat effective for viruses. Depending on source-water risk and local regulations, validated disinfection may also be necessary. (CDC home water-treatment guidance)
System Sizing Tool

Calculate Your WATCH UF 2500® Configuration

Determine the required number of parallel WATCH UF 2500® modules based on your peak commercial flow rate.

Each individual WATCH UF 2500 module provides a published nominal flow of 2.2–2.7 m³/h.

Configuration Recommendation

Get an ultrafiltration solution

It all starts with your source-water analysis and required flow.

Send us your source-water quality, peak flow requirements (m³/h), pressure and application details (hotel, RO pre-filtration, campsite, industrial). Our specialists will help evaluate WATCH UF 2500® for your installation.